Tested on an RX3 that is running well with no errors
( pins are correctly labelled)
Testing the procedure for P0107 Map Sensor low voltage (page 54-55)
-------------------------------------------------------------------------------
step2,
Cycled fault code P0108 & P0112 while running but when re assembled no current code remained.
step3,
4.96 v (stated range, above 4v)
Testing the procedure for P0108 MAP sensor high voltage (page 56)
----------------------------------------------------------------------------
step2,
Cycled fault code P0107 & P0112 while running but when re assembled no current code remained.
step3,
4.96v - (stated range, above 4v)
Testing the procedure for P0112 MAT sensor Low temp indicated (page 57 -58)
----------------------------------------------------------------------------
step2,
4.8v (stated range, above 4v)
step3,
4.94v (stated range, above 4v)
Testing the procedure for P0113 MAT sensor high temp indicated (page 59)
----------------------------------------------------------------------------
step2,
4.96v (stated range, above 4v)