View Single Post
Old 04-09-2024, 08:37 PM   #4
tknj99   tknj99 is online now
 
Join Date: Oct 2020
Location: Central VA
Posts: 1,255
Quote:
Originally Posted by Thumper View Post
My 6 speed Templar X starter had a short. It cranked weakly, even with a charged battery, or a jump. These symptoms made me wonder what was going on inside that new starter

I took it apart and found that the rotor windings armature was grazing a metal plate that the brushes mounted on. There was blackened evidence of the short on the plate and the tip of the armature...I used a dremel to shave both sides away from each other, cleaned and reassembled the starter with lube on both ends, and the thing worked perfectly.
Interesting.. the guy that bought my Templar X last year messaged me recently asking for advice related to issues starting as well.. based on what he said i told him it sounded like the starter.. wondering if it'll wind up being a known issue on these Templar X's as its not sounding like a coincidence as starters usually last alot longer than a year or so
__________________
2024 Zuma Storm 150 DLX
2019 Beta 430 RRS
2017 Honda Fury

Former China Bikes: Tao DBX1, Brozz 250, CSC RX4, Titan DLX, Templar X


 
Reply With Quote